Change log Module 3, current version is 25.0.0.2

This article makes it possible to track changes in Module 3 quickly and easily.

Note: This article is provided as a courtesy. It has been automatically translated using software and may not have been proofread. The German-language version is the official version and you can find the most up-to-date information there.

Version 25.0.0.2

- Fixed issue 2353811 for the Hilti girder part.

- Resolved validation crossing for Hilti issue 2332783 (Sikla SB F 194010, HEB-siframo 80).

- Enabled the part model to auto-detect based on the CAD version, eliminating the need to rename folders.

- Fixed a crash when selecting a profile (SetImpliedSelection).

- Enhanced the function for editing old connections to handle more scenarios.

- Added distance validation for X connections.

- Corrected the AKF selection to choose the correct type.

 

Version 25.0.0.1

Fix SetImpliedSelection crash

 

Version 25.0.0.0

- upgraded all features for compatibility with Plant3D and Advance Steel 2022 to 2025

- updated Patcher Profile and BOM

- standardized all commands to start with SuCri3 and follow Pascal case naming conventions

- added functionality to group bolts

 

Version 24.1.7.5

- SUCRI3_SET_LOCATIONPOINT can work with custom coordination. 

- Fixed an issue causing unintended movement of LOCATIONPOINT when copying.

- Updated profile angle validation rules so that a 360° angle is recognized as equivalent to 0°.

- Corrected a bug preventing connection placement when the system line was offset.

- Fix cannot moving old connection.

- Added the ability to modify old connection.

 

Version 24.1.7.4

- Corrected the AKF description. 

- Added a NoCap option for AKF and TKO.

- Fixed an issue causing incorrect cut length displays in special parts (AKF, TKO).

- Improved handling of combined consoles (AKF, TKO) to ensure proper operation with other connections.

- Resolved a crash in SUCRI3_BATCH_UPDATECONNECTIONS.

- Updated the user manual link.

- Update patcher can work with relative path.

 

Version 24.1.7.2

General Improvements:

- The format and appearance of the location points have been updated.

 

Version 24.1.7.1

Manufacturer-Specific Updates:

Sikla Extension:

- SB Connections for HEA, HEB, and IPE profiles have been added.

- Additional connections for TPF80/30 and TPF100/160 have been added.

General Improvements:

- A new command (SUCRI3_SET_TOLERANCE) has been introduced, allowing users to control the accuracy of the profiles in relation to each other and their angles.

- The ability to save connections permanently within the DWG has been introduced.

- Two new commands have been integrated: SUCRI3_SET_LOCATIONPOINT and SUCRI3_UPDATE_LOCATIONPOINT.

 

Version 24.1.7.0

Manufacturer-Specific Updates:

Sikla Extension:

- siMetrix Connections have been added

- The corner connectors CC 41-1 to CC 41-5 have been added

General Improvements:

- The SUCRI3_BATCH_UPDATECONNECTIONS function has been integrated.

- The SUCRI3_BATCH_UPDATEBLOCKS function has been integrated.

- The selection behaviour has been reversed so that SuCri follows the standard selection behaviour
Advance Steel selection behaviour.

- In the Connections interface, the option has been added to create a connection without
without connecting the profiles to each other.

- A SUCRI3_SETAUTO_WELD command has been integrated which controls the connection
of the individual components.

- All functions have been renamed to follow the same naming scheme.

 

Version 24.1.6.5

Manufacturer-specific changes:

Sikla Extension:

General improvements:

- Additional anchors have been added.

- Several WBD components have also been made available for the I connection.

- The patcher has been improved to allow starting it with arguments via the Windows
Command Prompt.

- The PartModels_2023 folder has been added.

- The patcher has been improved to automatically set the correct PartModels folder as active based on the selected version.

Bugfixes:

- An issue with the display of the position number on the drawing when using cantilever brackets 
and beam brackets has been resolved.

- The Sikla drawing bill of materials has been corrected to accurately calculate the
total weight of special parts on the drawing.

- An issue with the Import Brackets function has been resolved, which was causing a crash when no path was selected.

 

Version 24.1.6.3

General improvements:

- Advance Steel 2022-2024 now supported

- DB Patches are created again and fully supports now international version.

- Triplan Extension added in patching process

Bugfixes:

- Some Issues are fixed in patches

Manufacturer-specific changes:

Triplan Extension

- Triplan Extension are added

 

Version 24.1.6.0

General improvements:

- DB Patching Tool has been added.

Bugfixes:

- The component WBD F80 - 201/310 was incorrectly labelled.

Manufacturer-specific changes:

Sikla Extension

- Many new components have been added for SiFramo 80/30 and 160/100.

- Connections are now also possible to IPE100-300