Version 24.1.7.2

General Improvements:

- The format and appearance of the location points have been updated.

 

Version 24.1.7.1

Manufacturer-Specific Updates:

Sikla Extension:

- SB Connections for HEA, HEB, and IPE profiles have been added.
- Additional connections for TPF80/30 and TPF100/160 have been added.

General Improvements:

- A new command (SUCRI3_SET_TOLERANCE) has been introduced, allowing users to control the accuracy of the profiles in relation to each other and their angles.
- The ability to save connections permanently within the DWG has been introduced.
- Two new commands have been integrated: SUCRI3_SET_LOCATIONPOINT and SUCRI3_UPDATE_LOCATIONPOINT.

 


 

Version 24.1.7.0

Manufacturer-Specific Updates:

Sikla Extension:

- siMetrix Connections have been added
- The corner connectors CC 41-1 to CC 41-5 have been added

General Improvements:

- The SUCRI3_BATCH_UPDATECONNECTIONS function has been integrated
- The SUCRI3_BATCH_UPDATEBLOCKS function has been integrated
- The selection behaviour has been reversed so that SuCri follows the standard selection behaviour
Advance Steel selection behaviour.
- In the Connections interface, the option has been added to create a connection without
without connecting the profiles to each other
- A SUCRI3_SETAUTO_WELD command has been integrated which controls the connection
of the individual components
- All functions have been renamed to follow the same naming scheme.

 


 

Version 24.1.6.5

Manufacturer-specific changes:

Sikla Extension:

General improvements:

- Additional anchors have been added.
- Several WBD components have also been made available for the I connection.
- The patcher has been improved to allow starting it with arguments via the Windows
Command Prompt.
- The PartModels_2023 folder has been added.
- The patcher has been improved to automatically set the correct PartModels
folder as active based on the selected version.

Bugfixes:

- An issue with the display of the position number on the drawing when using cantilever brackets 
and beam brackets has been resolved.
- The Sikla drawing bill of materials has been corrected to accurately calculate the
total weight of special parts on the drawing.
- An issue with the Import Brackets function has been resolved, which was causing a crash when no path was selected.

 


 

Version 24.1.6.3

General improvements:

- Advance Steel 2022-2024 now supported
- DB Patches are created again and fully supports now international version
- Triplan Extension added in patching process

Bugfixes:

- Some Issues are fixed in patches

Manufacturer-specific changes:

Triplan Extension

- Triplan Extension are added

 


 

Version 24.1.6.0

General improvements:

- DB Patching Tool has been added.

Bugfixes:

- The component WBD F80 - 201/310 was incorrectly labelled.

Manufacturer-specific changes:

Sikla Extension

- Many new components have been added for SiFramo 80/30 and 160/100.
- Connections are now also possible to IPE100-300